Online NOx Analyzer for Continuous Emission Monitoring (CEMS)

update image

Z-105i Ein- Based on the Chemiluminescence Principle, the NOX analyzer adopts modular structure design and combines with advanced Microprocessing Technology to provide accurate and reliable low-concentration NOX detection of 'PPB~PPM' level, which can be applied to atmospheric detection and CEMS system (dilution method).

Features :

Measurement range from 0~500ppb to 0~20ppm, selectable.

Measure NO, NO2, NOX independently.

Installed with permeable drying tank on ozonator.

Bidirectional RS232 port for remote control.

Timed dark current compensation, high stability.

Adaptive signal filtering technology optimizes response time.

Large capacity memory, store historical data automatically.

Application

 Applied to atmospheric monitoring.

Specifications

Measuring range: 0~500ppb, 0~20,000ppb (adjustable)

Unit: ppb, ppm, ug/m3, mg/m3

Zero noise:<0.2ppb(RMS)

Limit of detection: 0.4ppb

Zero drift:<1ppb/24h  

Span drift:<5ppb/24h  

Response time:<120s (T90)  

Linearity:<1%/F.S.  

Repeatability:<1%  

Sampling flow range: 400SCCM±50SCCM

Ambient temperature: 5℃~40℃

Dimension: 178mmx430mmx635mm

Weight:<16kg, external pump of 5kg

Power: 200V~240V, 50/60Hz, 400W

Analog output: 10V, 5V, 1V, 0.1V (selectable)

Communication: RS232, RS485