Description
Online Flue Gas Analysis System – GPIPL Model Z-207i Ein, a highly integrated gas monitoring system based on TDLAS and DOAS technology for continuous online monitoring of flue gas components. The system is suitable for applications such as boiler flue gas, exhaust monitoring and denitrification systems. It features a single-flange design, high-temperature flow measurement, heat-traced gas path and automatic purging for reliable operation under high-dust conditions. The system supports multi-gas measurement, including CO, CO₂, SO₂, NO and NO₂, with ≤2% F.S. indication error, T90 ≤10 seconds response time, 4–20 mA analog outputs, RS485 communication, and 220 VAC, 50 Hz power supply. Specifications TDLAS Technical Index. Principle: TDLAS Range: CO: 0-1000ppm, CO2: 0~25% Indication error: ≤2%F.S. Repeatability: ≤2%F.S.Zero drift: ≤2%F.S./7d Span drift: ≤2%F.S./7d DOAS Technical Index Principle: DOAS Range: SO2: 0~1000ppm, NO: 0~1000ppm, NO2: 0~1000ppm Indication error: ≤2%F.S. Repeatability: ≤2%F.S. Zero drift: ≤2%F.S./7d Span drift: ≤2%F.S./7d Power: (220±15%)VAC, 50Hz, 600W Gas source: 0.4~0.8MPa, oil-free, water-free and dust-free Response time: T90≤10s (double modules) Analog output: 5x4-20mA output (depend on gas combination) Switch input: 4xRelay output Digital input: 1xRS485 output Ambient temperature: -20℃~60℃ Ambient humidity: ≤90%RH, non condensing