PLOT No. – 6, H Block, HadBast (HB) No 10 Vill - Mouja Saidpura, Barwala Road Derabassi PIN 140507 Punjab, India
08048057962
+919816111638

Z-15i Ein - TDLAS & DOAS FLUE GAS ANALYZER

FLUE GAS ANALYZER by GPIPL

Z-15i Ein - TDLAS & DOAS FLUE GAS ANALYZER

Phone Number

Email Address sales@gpiint.com

Mon-Thu: 10 AM - 2 PM • Fri: 3 PM - 7AM

Other Website Visit our other website
Address India

PLOT No. – 6, H Block, HadBast (HB) No 10 Vill - Mouja Saidpura, Barwala Road Derabassi PIN 140507 Punjab, India, India, 140507

Description

In-situ online gas pollution monitoring system using TDLAS & DOAS technology for real-time, continuous, high-accuracy measurement of flue gas components (SO₂, NOx, CO, CO₂, NH₃, O₂) directly in the stack without sample extraction. AVALIABLE IN STOCK Online Flue Gas Pollution Monitoring System Using TDLAS & DOAS In-Situ Gas Analyzer In-Situ TDLAS & DOAS Flue Gas Analyzer for Continuous Emission Monitoring Advanced Gas Pollution Monitoring: TDLAS & DOAS In-Situ Analyzer for Flue Gas Continuous In-Situ Flue Gas Monitoring Using TDLAS and DOAS Technologies Real-Time Emission Monitoring with TDLAS & DOAS In-Situ Gas Analyzer Specifications TDLAS Technical Index. Principle: TDLAS Range: CO: 0-1000ppm, CO2 : 0~25% Indication error: ≤2%F.S. Repeatability: ≤2%F.S.Zero drift: ≤2%F.S./7d Span drift: ≤2%F.S./7d DOAS Technical Index Principle: DOAS Range: SO2: 0~1000ppm, NO: 0~1000ppm, NO2: 0~1000ppm Indication error: ≤2%F.S. Repeatability: ≤2%F.S. Zero drift: ≤2%F.S./7d Span drift: ≤2%F.S./7d Power: (220±15%)VAC, 50Hz, 600W Gas source: 0.4~0.8MPa, oil-free, water-free and dust-free Response time: T90≤10s (double modules) Analog output: 5x4-20mA output (depend on gas combination) Switch input: 4xRelay output Digital input: 1xRS485 output Ambient temperature: -20℃~60℃ Ambient humidity: ≤90%RH, non condensing

Other Products

view all

6814772a5d263414004dd4a4 Card 2

product image
Environmental Air Quality Monitoring System

Z-102i Ein - Micro Environment Air Monitoring System is a small online environmental monitoring system based on high precision (ppb level) gas sensor. It provides flexible sensor combination scheme and modular design, as well as online monitoring of PM10, PM2.5, SO2, NO2, O3, CO, VOCs, temperature, humidity and other factors in the atmosphere. Special factors can also be quickly configured according to the actual environmental monitoring requirements. The system is equipped with special temperature control system and sensing module to improve the environmental adaptability of the system and ensure the accuracy of monitoring data. Compared with conventional air stations, this system can realize high-density grid layout, achieve air pollution monitoring with high spatial and temporal resolution, and provide more timely and effective decision support for the pre-warning and prevention of environmental air pollution by combining the functions of Big Data, including environmental pollution source tracking and environmental pollution pre-warning and prediction, etc.

6814772a5d263414004dd4a4 Card 2

product image
Cold Dry Continuous Emission Monitoring System (CEMS)

Based on standard Continuous Emission Monitoring System (Condensation), our company has developed a Positive-pressure Explosion-proof Continuous Emission Monitoring System. Z-51i Ein Continuous Emission Monitoring System is composed by explosion-proof dust monitoring subsystem, explosion-proof gaseous pollutant monitoring subsystem, explosion-proof flue gas parameter monitoring subsystem, and system control & data acquisition & processing subsystem. It can monitor SO2, NOX, O2, dust, temperature, pressure, velocity, etc. Other parameters can be extended as required for special occasions, such as HCl, HF, CO, CO2, humidity, etc

6814772a5d263414004dd4a4 Card 2

product image
Nitrogen Oxides Analyzer

Based on the Chemiluminescence Principle, the NOX analyzer adopts modular structure design and combines with advanced Microprocessing Technology to provide accurate and reliable low-concentration NOX detection of 'PPB~PPM' level, which can be applied to atmospheric detection and CEMS system (dilution method). Features: Measurement range from 0~500ppb to 0~20ppm, selectable. Measure NO, NO2, NOX independently. Installed with permeable drying tank on ozonator. Bidirectional RS232 port for remote control. Timed dark current compensation, high stability. Adaptive signal filtering technology optimizes response time. Large capacity memory, store historical data automatically. Application Applied to atmospheric monitoring. Specifications Measuring range: 0~500ppb, 0~20,000ppb (adjustable) Unit: ppb, ppm, ug/m3, mg/m3 Zero noise:<0.2ppb(RMS) Limit of detection: 0.4ppb Zero drift:<1ppb/24h Span drift:<5ppb/24h Response time:<120s (T90) Linearity:<1%/F.S. Repeatability:<1% Sampling flow range: 400SCCM±50SCCM Ambient temperature: 5℃~40℃ Dimension: 178mmx430mmx635mm Weight:<16kg, external pump of 5kg Power: 200V~240V, 50/60Hz, 400W Analog output: 10V, 5V, 1V, 0.1V (selectable) Communication: RS232, RS485